Simply Hosting & Servers Outage History

Simply Hosting & Servers is up right now

Pingoru has recorded 47 incidents for Simply Hosting & Servers: 6 in the last 12 months and 1 in the last 90 days.

Source: status.simplyhosting.com

47incidents recorded
6last 12 months
1last 90 days
16 hourstypical duration
Incidents per month
012AprMayJunJulAugSepOct0
Share of hours with an open incident, any severity
0%50%100%AprMayJunJulAugSepOct0%
Pingoru began tracking Simply Hosting & Servers in April 2026, so earlier months are not shown. Hover a bar for its value.
Show as a table
MonthIncidentsHours with an open incident
April 202600 of 720 (0%)
May 202611 of 744 (0%)
June 202600 of 720 (0%)
July 2026171 of 744 (10%)
August 202600 of 744 (0%)
September 2026111 of 720 (2%)
October 202600 of 514 (0%)

Incidents, newest first

Notice September 28, 2026 Network at risk - Carrier line down 10h 47m Network Status

Started Sep 28, 2026, 08:45 AM UTC· resolved Sep 28, 2026, 07:32 PM UTC

  1. investigating Sep 28, 2026, 08:45 AM UTC

    One of our UK to Ireland links is currently down. The Redundant paths are functioning as expect so no impact is expected but the network should be considered at risk at this time. We have a case open with the carrier and are awaiting updates.

  2. resolved Sep 28, 2026, 07:32 PM UTC

    One of our UK to Ireland links is currently down. The Redundant paths are functioning as expect so no impact is expected but the network should be considered at risk at this time. We have a case open with the carrier and are awaiting updates. The Carrier has confirmed the issue is resolved, we have monitored and are happy to now end the at risk period.

Read the full incident report →

Notice July 10, 2026 Suspected fibre issue between sites - Network at risk. 2d 22h Network Status

Started Jul 10, 2026, 09:21 AM UTC· resolved Jul 13, 2026, 08:08 AM UTC

  1. investigating Jul 10, 2026, 09:21 AM UTC

    We are currently dealing with a issue on one of our fibre connections. Any services using it have failed over to redundant resources but the network should be considered "At Risk" while this fault is ongoing.

  2. investigating Jul 10, 2026, 03:55 PM UTC

    We are currently dealing with a issue on one of our fibre connections. Any services using it have failed over to redundant resources but the network should be considered "At Risk" while this fault is ongoing. The carrier has now identified the issue and is working to carry out the necessary repairs.

  3. monitoring Jul 10, 2026, 11:04 PM UTC

    The carrier has repaired the service and the normal levels of resilience of the network have resumed. We consider the event cleared, but will continue a period of monitoring.

  4. resolved Jul 13, 2026, 08:08 AM UTC

    The carrier has repaired the service and the normal levels of resilience of the network have resumed. We consider the event cleared and are no longer in an at risk state.

Read the full incident report →

Notice May 15, 2026 Switch failure in 1 rack - Reading L20 1h 4m

Started May 15, 2026, 12:23 PM UTC· resolved May 15, 2026, 01:28 PM UTC

  1. investigating May 15, 2026, 12:23 PM UTC

    Our monitoring has identified a failed network switch in our Reading datacentre rack L20 affecting a small number of dedicated server customers in that rack. The switch is currently under investigation and we expect servers to return online soon. We will post a further update once complete.

  2. monitoring May 15, 2026, 01:12 PM UTC

    A fix has been implemented and we are monitoring the results.

  3. resolved May 15, 2026, 01:28 PM UTC

    This incident has been resolved.

Read the full incident report →

Notice March 27, 2026 Switch failure in 1 rack - Reading N17 4h 28m

Started Mar 27, 2026, 12:41 PM UTC· resolved Mar 27, 2026, 05:10 PM UTC

  1. identified Mar 27, 2026, 12:41 PM UTC

    Our monitoring has identified a failed network switch in our Reading datacentre rack N17 affecting a small number of dedicated server customers in that rack. The switch is currently under replacement and we expect servers to return online soon. We will post a further update once complete.

  2. identified Mar 27, 2026, 01:08 PM UTC

    The switch has now been replaced, and the rack is back online

  3. monitoring Mar 27, 2026, 01:10 PM UTC

    We will continue to monitor over the next couple of hours

  4. resolved Mar 27, 2026, 05:10 PM UTC

    This incident has been resolved.

Read the full incident report →

Notice February 3, 2026 Network Issue 7h 31m Network Status

Started Feb 03, 2026, 09:27 AM UTC· resolved Feb 03, 2026, 04:59 PM UTC

  1. investigating Feb 03, 2026, 09:27 AM UTC

    We are investigating an issue on one link between our Reading Datacentre and London, this link is currently down and therefore the network should be considered at-risk. We are engaging with our upstream supplier to determine a root cause and implement a fix.

  2. investigating Feb 03, 2026, 03:53 PM UTC

    Our supplier has identified the root cause and is undertaking remedial work to address the underlying issue. The network remains at risk at this time.

  3. investigating Feb 03, 2026, 04:52 PM UTC

    Our supplier has completed the remedial work and confirmed the fix is in place. The network is no longer at risk. We will continue to monitor the link overnight as a precaution.

  4. resolved Feb 03, 2026, 04:59 PM UTC

    This incident has been resolved.

Read the full incident report →

Minor October 24, 2025 Switch Failure 2h 44m Network Status

Started Oct 24, 2025, 01:10 PM UTC· resolved Oct 24, 2025, 03:54 PM UTC

  1. investigating Oct 24, 2025, 01:10 PM UTC

    We currently have an issue with one of our switches causing some servers to be offline, we are working on getting the issue resolved.

  2. identified Oct 24, 2025, 01:11 PM UTC

    The issue has been identified and a fix is being implemented.

  3. resolved Oct 24, 2025, 03:54 PM UTC

    This incident has been resolved.

Read the full incident report →

Notice October 2, 2025 Network Circuit Issues 18h Network Status

Started Oct 02, 2025, 01:36 PM UTC· resolved Oct 03, 2025, 07:37 AM UTC

  1. investigating Oct 02, 2025, 01:36 PM UTC

    Our monitoring has detected 2 independent issues on circuits to our other European locations. Whilst we still have upstream connectivtiy from that location and resilient connectivity to another core pop datacenter we as such rely on this site at the current time and would consider this an at-risk situation for Network. We are progressing fault tickets with both carriers with the highest priority to restore normal resilience levels.

  2. investigating Oct 02, 2025, 06:23 PM UTC

    Both suppliers of different international circuits are mobilising engineers and replacement equipment to their affected locations in the EU with priority.

  3. resolved Oct 03, 2025, 07:37 AM UTC

    Both suppliers of different international circuits have repaired their services overnight in the EU. The Network is now operating with normally expected levels of resilience.

Read the full incident report →

Major June 17, 2025 Network Status 2d 2h Network Status

Started Jun 17, 2025, 08:04 AM UTC· resolved Jun 19, 2025, 10:11 AM UTC

  1. investigating Jun 17, 2025, 08:04 AM UTC

    Our network teams have identified multiple independent fibre cuts across multiple suppliers that are impacting usual resilience to our IP transit network that feeds our UK hosting services. The network is still available and at full capacity, however we consider this an at-risk situation until these links are recovered by the suppliers and are closely tracking their progress.

  2. monitoring Jun 17, 2025, 06:52 PM UTC

    All fibres and links are now available as normal and full network resilience has been restored. We will keep under monitoring overnight but are not anticipating any further unplanned works.

  3. resolved Jun 19, 2025, 10:11 AM UTC

    All fibres and links are now available as normal and full network resilience has been restored. We will keep under monitoring overnight but are not anticipating any further unplanned works.

Read the full incident report →