Optum incident
Resolved Notice: CENTRAL SERVICE WSO2 (CHC) - Pharmacy customers are unable to search and validate prescribe information
Optum experienced a major incident on March 6, 2026 affecting Pharmacy Software Solutions, lasting 2h 14m. The incident has been resolved; the full update timeline is below.
Affected components
Update timeline
- investigating Mar 06, 2026, 01:10 PM UTC
We are aware of an issue with Central Prescriber resulting in failures during Prescriber searches. We are actively working with the vendor to resolve. #INC48793810
- identified Mar 06, 2026, 02:05 PM UTC
The issue has been identified as a certificate issue with Lexis Nexis. We are working with them to resolve. #INC48793810
- identified Mar 06, 2026, 03:01 PM UTC
We have identified the issue as a result of a certificate change implemented by LexisNexis and are actively working with LexisNexis to install the updated certificate. We will continue to provide updates as progress is made. #INC48793810
- resolved Mar 06, 2026, 03:24 PM UTC
The Central Prescriber issue has been resolved; LexisNexis has reverted their change. #INC48793810