brainCloud incident

Another primary mongodb server has become unreachable...

Resolved after 1 hour 40 minutes, affecting Design Portal, on September 27, 2021.

resolved Sep 27, 2021, 04:47 AM UTC

Amazon has identified an issue with EBS instances in one of the zones of us-east-1 where brainCloud is hosted. We have migrated servers out of the affected zone. It turns out that in 2 scenarios, we had multiple instances of the same shard in the same zone - which interfered with MongoDB's ability to fail over when the zone failed. We will put additional processes in place to avoid this configuration issue in the future. Apologies!

Started
Sep 27, 2021, 03:06 AM UTC
Resolved
Sep 27, 2021, 04:47 AM UTC
Duration
1h 40m
Detected by Pingoru
Sep 27, 2021, 03:06 AM UTC

Affected components

Design Portal

Update timeline

  1. investigating Sep 27, 2021, 03:06 AM UTC

    We believe there are networking issues happening within the cluster...

  2. identified Sep 27, 2021, 03:19 AM UTC

    It looks like this is an Amazon EBS issue - they are now showing a status that EBS connections in the North Virginia region (where we are) are impaired. This is what is impacting our database.

  3. resolved Sep 27, 2021, 04:47 AM UTC

    Amazon has identified an issue with EBS instances in one of the zones of us-east-1 where brainCloud is hosted. We have migrated servers out of the affected zone. It turns out that in 2 scenarios, we had multiple instances of the same shard in the same zone - which interfered with MongoDB's ability to fail over when the zone failed. We will put additional processes in place to avoid this configuration issue in the future. Apologies!

Your product runs on more than brainCloud

Add the vendors you depend on and get one message when any of them reports trouble. Free for 3 vendors, no card.

Add your stack →