SecureCo incident

Gen1 Upstream Carrier Path Degradation

Notice Resolved View vendor source →

SecureCo experienced a notice incident on November 25, 2024 affecting Gen1 - Carrier Services, lasting 18h 18m. The incident has been resolved; the full update timeline is below.

Started
Nov 25, 2024, 04:52 AM UTC
Resolved
Nov 25, 2024, 11:10 PM UTC
Duration
18h 18m
Detected by Pingoru
Nov 25, 2024, 04:52 AM UTC

Affected components

Gen1 - Carrier Services

Update timeline

  1. investigating Nov 25, 2024, 04:52 AM UTC

    We are currently investgating alarms and reports of an upstream carrier path in our Gen1 network failing to connect calls. Investgations have commenced with the upstream carrier to identify the issue.

  2. identified Nov 25, 2024, 05:19 AM UTC

    We have identified the issue with the upstream carrier path and working on a work around solution.

  3. identified Nov 25, 2024, 06:49 AM UTC

    We are engage in ongoing works with our Carrier Partner to resolve the issue. The issue effects calls to tollfree numbers which route via URI to SecureCo to our SYD1 pop. Customers with inbound Toll Free numbers are advised to ensure they have configured their Toll-Free Call routing plan to use both SYD1 and SYD2 URI, as well as PSTN failover to ensure calls successfully terminate to the required Answerpoint.

  4. identified Nov 25, 2024, 10:57 PM UTC

    Services are restored and under Monitoring.

  5. resolved Nov 25, 2024, 11:10 PM UTC

    This incident has been resolved.